Elevation extraction
A network imported from GIS or generated from a location often arrives with no levels, or with ground levels and no inverts. Nothing in SWMM matters more: a sewer model with wrong elevations is not an approximate model, it is a model of a different network.
Model data ▸ Elevation Extraction (DEM) extracts, interpolates and assigns real ground and invert elevations from a terrain model.
What it does
Section titled “What it does”- Extracts a ground elevation at each node from the terrain source.
- Interpolates where the terrain has no value at that exact point.
- Assigns the result as the node’s rim level, and derives an invert from it.
Inverts come from a cover depth rather than from the terrain directly, because a manhole invert is a construction depth below the surface, not a property of the ground.
Re-grading for gravity flow
Section titled “Re-grading for gravity flow”Extracted levels alone do not guarantee a network that drains. Terrain is noisy, cover depth is a rule of thumb, and the result is often a run of pipes with an adverse or a flat section in the middle.
Re-grading walks the network from its outfalls and enforces a minimum slope on each conduit, deepening nodes where it has to. The outcome is a network that at least drains in the direction it was drawn.
Checking the result
Section titled “Checking the result”Three checks catch nearly everything:
- Trace network ▸ Reverse adverse-slope conduits finds pipes still running uphill.
- The profile view shows the long section, where an unreasonable depth or a sawtooth invert is obvious.
- Network statistics reports the node elevation range. A range of two kilometres in a town is a units or datum problem, not a terrain one.
Related
Section titled “Related”- Generating a model from a location · where extraction usually follows
- Repairing network topology · the other post-import fix