Sewer condition grading (PACP, MSCC, EN 13508)
A CCTV survey records defects in a pipe, which roll up to a 1-5 condition grade. That grade is the strongest single input to an asset’s probability of failure (PoF). The catch is that the scale, and even its direction, differs by regime - so SWMM Web asks which standard your data uses and normalises everything to one internal scale.
The standards
Section titled “The standards”| Region | Standard | Scale | Worst end | Regulatory driver |
|---|---|---|---|---|
| US / Canada | NASSCO PACP (Pipeline Assessment & Certification Program) | 1-5, separate structural + O&M grades | 5 = worst | EPA CMOM programs, consent-decree asset-management plans |
| UK | WRc MSCC5 / SRM (Manual of Sewer Condition Classification) | 1-5, separate structural + service grades | 5 = worst | OFWAT asset health, the Sewerage Risk Management framework |
| Europe | EN 13508-2 coding + national grading (e.g. Germany DWA-M 149) | usually 0-5 | varies - often 0 = worst | EU Urban Waste Water Treatment Directive |
Two things that catch people out
Section titled “Two things that catch people out”Structural vs service. PACP and MSCC each produce two grades: a structural grade (cracks, fractures, collapse - the probability of failure) and a service / O&M grade (blockages, roots, flow - an operational nuisance). For asset-risk PoF you want the structural grade; the service grade is stored for reference but does not drive failure probability.
How SWMM Web uses it
Section titled “How SWMM Web uses it”When you import condition data (from the asset risk register), you choose the grading scheme. SWMM Web then:
- Normalises the structural grade to an internal 1 (as-new) - 5 (worst) scale, flipping the inverted EU polarity automatically.
- Uses that grade as the condition aspect of PoF, which overrides the age-vs-material deterioration curve when present (a real inspection beats an estimate).
- Keeps the service grade alongside for reference.
So a mixed dataset - PACP for one basin, MSCC for another - can be imported in two passes and still score consistently on one register.
Field mapping
Section titled “Field mapping”The importer auto-detects columns by name (e.g. PACP_Struct, YearLaid, PipeMat)
and lets you correct the mapping. You need a conduit ID column to join to the model;
material, install year, structural grade and service grade are all optional - import
whatever you have.