Options and units

Open Calculation options from the toolbar gear.

SWMM does not convert units, it reinterprets them. The flow unit you choose declares which system the whole model is in:

Flow unitSystemLengthsAreasRain
CFS, GPM, MGDUS customaryftacresin/hr
CMS, LPS, MLDMetricmhectaresmm/hr

Everything in the application follows the model’s system, including thresholds. A self-cleansing velocity of 0.6 m/s and 2.0 ft/s are the same rule expressed in each system.

MethodUse it when
Steady flowQuick screening only. No storage, no backwater.
Kinematic waveFast, stable, branched networks. Cannot represent backwater or surcharge.
Dynamic waveAnything with pressurised flow, backwater, loops, pumps, weirs or storage.

Dynamic wave is required for CSO structures and any surcharging network, and it is the reason long runs take real time. If you are modelling overflows, this is not optional.

  • Routing step is the hydraulic solver’s step. Too long and continuity error climbs.
  • Wet and dry steps control runoff calculation during and between storms.
  • Report step is how often results are written. It does not affect accuracy, only resolution and file size.

Start and end date and time define the simulation window. Total duration is derived, and editing it moves the end date.

For a design storm, allow enough time after the rain stops for the network to drain, or you will cut off the peak you were trying to see.

  1. Flow units match the model’s actual units.
  2. Routing method suits the network (dynamic wave if anything surcharges).
  3. Duration covers the storm and the recession.
  4. After running, continuity error is small.