Profile and HGL
The profile is the classic sewer drawing: pipe inverts stepping down a flow path, the ground surface above them, and after a run the hydraulic grade line showing where the water actually stands. It answers a question the map cannot - not which pipes surcharge, but why, and what the water level is doing along the whole route.
Drawing one
Section titled “Drawing one”-
Open Profile from the toolbar.
-
Pick a start and an end node. The path between them is found automatically.
-
Run the model if you have not already. Without results you get the geometry - inverts, barrels, manholes, ground line - which is useful on its own for checking a build.
The path follows any link type, not just conduits: orifices, weirs, pumps and outlets are all traversed. That matters on a real network, because a detention pond usually discharges through a weir or orifice rather than a pipe, and a path restricted to conduits would stop dead at the pond.
Reading it
Section titled “Reading it”| What you see | What it means |
|---|---|
| HGL inside the barrel | Free-surface flow. The pipe has capacity in hand |
| HGL at the pipe soffit | Running full - at capacity, no freeboard |
| HGL above the soffit | Surcharged. The pipe is pressurised and backing up |
| HGL above the ground line | Flooding. Water is out of the manhole at that node |
The slope of the HGL is the hydraulic gradient, so a steep section is where head is being lost. A long flat HGL upstream of a constriction is backwater, and the constriction is at its downstream end, not where the flat section starts.
When the profile is the right tool
Section titled “When the profile is the right tool”Diagnosing flooding. The map shows you a flooded node. The profile shows you the run of pipe that put it there.
Checking a design change. Draw the same path before and after upsizing, and the HGL drop is the benefit, in metres of head rather than a percentage.
Sanity-checking a new model. Adverse slopes, inverts above ground, and pipes that step the wrong way are obvious in profile and nearly invisible in plan. Worth one look along every main trunk before trusting a freshly built or imported network. The network trace checks find these systematically.