Skip to content

Culvert design

Culverts are sized by the headwater they cause, following the FHWA HDS-5 method.

Inlet control - the entrance is the bottleneck. Capacity depends on the inlet geometry and edge treatment, not on the barrel length or roughness.

Outlet control - the barrel and the downstream water level govern. Length, roughness and tailwater all matter.

The tool computes both and reports the governing one, because the real headwater is the higher of the two. Which one governs tells you what to change: under inlet control, improve the entrance or add a barrel; under outlet control, the barrel or the tailwater is the problem.

Barrel shape and size, number of barrels, length, slope, roughness, entrance type, design flow, tailwater, and the allowable headwater.

Entrance type matters more than people expect. A projecting pipe end and a properly bevelled headwall can differ by a substantial margin in headwater for identical flow.

The governing headwater depth with the inlet- and outlet-control values behind it, the governing control, the headwater to diameter ratio, flow per barrel, critical depth and outlet velocity.

Place on map… or Add between new nodes writes the culvert into the model as a conduit with the culvert cross-section, its entrance loss and the FHWA inlet code. Re-run the model to see it working against the rest of the network.