Glossary
Antecedent dry period - time since the last storm. Drives how much pollutant has built up on surfaces.
Continuity error - the percentage of water the model failed to account for. Under about 1 percent is good; above 5 percent the results are not trustworthy.
CSO - combined sewer overflow. A structure that discharges to a watercourse when the combined system exceeds capacity, protecting the network from surcharge.
d/D - depth over diameter. How full a pipe ran. 1.0 means completely full. For a
circular pipe, d/D = 0.5 is exactly half the full-bore capacity.
Dry-weather flow (DWF) - sanitary flow when it is not raining.
Dynamic wave - the full hydraulic routing method. Required for backwater, surcharge, pressurised flow, loops and overflow structures.
First flush - the early part of a storm carrying a disproportionate pollutant load, because build-up is mobilised quickly and then depleted.
Freeboard - spare depth between the peak water level and the node rim. Negative means the node surcharged above ground.
Froude number - ratio of inertial to gravitational force. Below 1 is subcritical, above 1 supercritical. Near 1 the flow is unstable.
Hydraulic grade line (HGL) - the water surface elevation along a pipe run. Visible in the profile view; rising above the pipe crown means surcharge.
I&I - infiltration and inflow. Water entering a foul sewer that is not sewage.
Kinematic wave - a simplified routing method. Fast and stable, but cannot represent backwater or surcharge.
LID - low-impact development. Source controls such as permeable paving and bio-retention.
Manning’s n - roughness coefficient. Typically 0.013 for concrete or plastic pipe.
NSE - Nash-Sutcliffe efficiency, a calibration measure. 1.0 is perfect; 0 means the
model is no better than using the mean of the observations.
PBIAS - percent bias. Systematic over- or under-prediction in calibration.
Pollutograph - concentration plotted against time, the quality equivalent of a hydrograph.
RDII - rainfall-derived infiltration and inflow. The part of I&I that responds to rain. Modelled with RTK unit hydrographs.
RTK - the three-triangle unit hydrograph method for RDII. R is the fraction of
rainfall entering the sewer, T the hours to peak, K the recession ratio.
Self-cleansing velocity - the minimum velocity that keeps solids in suspension, around 0.6 m/s or 2 ft/s. Below it, solids deposit and the sewer becomes septic.
Subcatchment - an area of land whose runoff drains to one point.
Surcharge - flow under pressure, above the pipe crown. Not the same as flooding, which is water leaving the system.
Thiessen polygon - nearest-node area allocation. Each point owns the area closer to it than to any other point.
Time of concentration (Tc) - time for runoff to travel from the furthest point of a catchment to the point of interest. Determines which rainfall duration is relevant.