Deposition screening

Blockage scenarios answer what if this pipe silts up. Deposition screening answers the question before it: which pipes are likely to.

Open Operations & reports ▸ Blockages (partial obstruction), then the Deposition screening section. It reads the velocities from a completed run, so run the model first.

For each pipe, the fraction of the run spent below the self-cleansing criterion, banded as a likelihood:

BandMeaning
Highbelow the criterion for 90% or more of the time it conveys
Moderatebelow for 50% or more
Lowbelow for less than half
Never conveysessentially dry for the whole run

Velocity (the default) uses a fixed self-cleansing velocity, default 0.75 m/s, the middle of the conventional 0.6-1.0 m/s band. Simple, and the figure most design standards quote. It is editable.

Shear stress is the better physics. Deposition is resisted by the bed shear a flow imposes, τ = ρgRS_f, and the friction slope comes from the same Manning relation the engine itself uses. A large pipe and a small pipe at the same velocity do not impose the same shear.

The critical shear comes from one of two routes, and you choose:

  • Shields, τ_c = θ_c (ρ_s − ρ) g d, from an editable grain size (default 0.6 mm sewer grit), sediment density (2650 kg/m³, quartz sand) and Shields parameter (0.055). For 0.3-1.0 mm grit this yields roughly 0.27-0.89 N/m².
  • Design practice, a flat 2.0 N/m², the combined-sewer rule of thumb. Two to three times Shields, because the design figure carries cohesion, organics and a margin that Shields, describing clean sand at the point of motion, does not.

Both are computed and shown together, with the discrepancy visible, because the criterion changes the answer and neither is universally the strict one. On the Lebanon storm network the large pipes are steep and run at 17-20 ft/s, so their shear is enormous and the shear screen is the more permissive of the two: 60 pipes flagged against the velocity rule’s 70. The two disagree about roughly a tenth of the network, in both directions.

The threshold is held in SI and converted only for display, so a US customary model shows ft/s and lb/ft² without the underlying criterion changing. Shear is SI by construction while the friction slope mirrors the engine and works in feet, which is exactly the kind of place a units bug hides, so the conversions are explicit and separately tested.

On Warkworth almost every pipe screens as at risk. That is not a bug, it is a flat sanitary network that rarely reaches 0.75 m/s in dry weather, and it is worth knowing. Deposition screening is most discriminating on networks with a spread of gradients.

Requires a Pro plan.