Skip to content

Blockages and criticality

Most sewer incidents are not a collapsed pipe. They are a pipe half full of fat, silt or debris, still flowing, just not flowing enough. Open Operations & reports ▸ Blockages (partial obstruction).

A blockage is applied as real reduced geometry, using SWMM’s native FILLED_CIRCULAR cross-section: the silt depth that produces the requested loss of area is solved for, and the engine then routes flow through the shape that is actually left.

That matters. The obvious shortcuts are worse:

  • An orifice proxy at the pipe end changes the local head loss but leaves the conveyance of the pipe itself untouched.
  • Disabling the pipe models a total blockage, which is the rare case and grossly overstates the common one.
  • A TSS-triggered control rule cannot be written at all. SWMM’s control syntax has no concentration attribute, so a rule that reads a pollutant is simply invalid.

Pick the pipes on the map, or select one and add it, then set the % of area blocked for each. The tool runs the model with and without the obstruction and reports newly flooded nodes, nodes made worse, extra volume to the surface and the capacity left in the blocked pipes.

Only pipes that can physically be filled are offered: circular, filled-circular and rectangular shapes. A force main is excluded, and the tool says why rather than quietly skipping it.

The more useful operational question is not what if this pipe blocks but which pipe, if it blocked, would hurt most. The Criticality sweep blocks each candidate in turn, runs the model for each, and ranks them by consequence: nodes newly flooded, volume to the surface, and which node floods worst.

Pipe ids and node ids in the results are clickable and fly the map to the asset.

The sweep ranks the candidates it examined, not the whole network, and the summary says so with the number examined. Shortlist by most flow or closest to full, and set how many candidates to test.

Requires a Pro plan.